If you register, you can do a lot more. And become an active part of our growing community. You'll have access to hidden forums, and enjoy the ability of replying and starting conversations.

The Pennine Moors Christmas Cracker 18/12/21.

الموضوع في 'What's Going On' بواسطة sgthompson, بتاريخ ‏29 نوفمبر 2021.

  1. Sheff

    Sheff Resident of Nat Pres

    إنضم إلينا في:
    ‏21 إبريل 2006
    المشاركات:
    8,084
    عدد المعجبين:
    3,148
    الجنس:
    ذكر
    الوظيفة:
    Retired Engineer & Heritage Volunteer
    مكان الإقامة:
    N Warks
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    I’m still wondering what befell her too.


    Sent from my iPad using Tapatalk
     
  2. Big Al

    Big Al Nat Pres stalwart Staff Member Moderator

    إنضم إلينا في:
    ‏30 ماي 2009
    المشاركات:
    22,740
    عدد المعجبين:
    22,895
    مكان الإقامة:
    1016
    Heritage Railway Volunteer:
    No I do not currently volunteer
    Well a continuous stream of water running out of an injector drain when there is no obvious reason why water should be going anywhere does suggest - at a guess - that an injector feed water valve has failed but that is quite unusual. That said, if there is no means to maintain the right level of water in the boiler it's little wonder that the fire had to go or you would also lose a plug or two.
     
    أعجب بهذه المشاركة green five
  3. Sheff

    Sheff Resident of Nat Pres

    إنضم إلينا في:
    ‏21 إبريل 2006
    المشاركات:
    8,084
    عدد المعجبين:
    3,148
    الجنس:
    ذكر
    الوظيفة:
    Retired Engineer & Heritage Volunteer
    مكان الإقامة:
    N Warks
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    I’d only see a still pic, so wasn’t aware of duration of said issue.


    Sent from my iPhone using Tapatalk
     
  4. Sidmouth

    Sidmouth Resident of Nat Pres Staff Member Moderator

    إنضم إلينا في:
    ‏12 سبتمبر 2005
    المشاركات:
    10,176
    عدد المعجبين:
    9,840
    الجنس:
    ذكر
    مكان الإقامة:
    Alderan !
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    I think in this instance the feed from the tender has been inadvertantly left on so not an injector failure

    Whilst I appreciate we are interested to know what caused the failure , until there is word from the owners we may need to be patient and not engage in too much speculation
     
  5. Big Al

    Big Al Nat Pres stalwart Staff Member Moderator

    إنضم إلينا في:
    ‏30 ماي 2009
    المشاركات:
    22,740
    عدد المعجبين:
    22,895
    مكان الإقامة:
    1016
    Heritage Railway Volunteer:
    No I do not currently volunteer
    Leaving the feed from the tender on 'inadvertently' is a strange thing to do, is it not unless for some reason you want to keep the injector cool? But anyway, a sad incident.
     
  6. Apollo12

    Apollo12 New Member

    إنضم إلينا في:
    ‏22 ماي 2020
    المشاركات:
    62
    عدد المعجبين:
    184
    الجنس:
    ذكر
    مكان الإقامة:
    North East
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    Anyone who’s ever operated a steam engine will have done that at some point, nothing strange about it at all it’s easily done. I had to tell someone firing to shut the water valve twice the other day as they’d forgotten.

    Not for one moment suggesting that’s what’s happened with 6100.
     
    26D_M و jonathonag معجبون بهذا.

مشاركة هذه الصفحة